Description | Parameters |
---|---|
Valve size suitable for the Testing criteria of this Machine | 1/2'' to 3 '' |
Valve class suitable for the Testing criteria of this Machine | #150 to #2500 |
Valve Type | Gate ,Globe, Check and Ball Valves |
Maximum Working Pressure | 700 Bar ( 10,150 PSI) |
No of Station | 6 |
Maximum Clamping Tonnage | 25 TON |
25 Ton – 6 Station
- Function : High Pressure Leakage Test .
- Clamping Method : Compression and Control clamping .
- Test Medium :Hydro and Air .
- Booster Pump Ratio : 1 : 157 ( Teslead Make) .
- Enhanced with PLC ,HMI and SCADA for Interlocking and Data Logging Purpose.
- Computerized data logging system will manage the VTR, and a Time vs. Pressure Graph will be plotted automatically to avoid human error.
- Additional Main Features: Testing Shell, Hand Detecting Sensors, Door Interlocking Sensors ,Sliding Arm for Quick Loading the Test Valve in Test Bunk and Bubble Counter for Gas and Pneumatic Test
Category: Multi station Test stand